Pressure Measurement and Control

Pressure is the next most important parameter after Temperature. In Hydraulics and Pneumatics, the measurement, indication, control and logging-charting of pressure is indispensable.

Popular Pressure Sensors are based on either Piezoresistive or Strain-Gauge Technologies. Strain-Gauge types can be Metal Foil or Semiconductor Film.

Pressure and Flow Control Applications - delabs

The Analog Strip Chart Recorder is used in Simple Systems where a Record or Report has to be generated. Data Loggers and PC based Data Acquisition Systems expand this capability by making the Data Electronically Accessible for Charting-Analysis and Reporting using database applications.
The Liquid-Fluid Level in containers of uniform cross-section can be computed by measuring the pressure of the fluid head. In cases where levels of semi-volatile fluids are measured, sensors with Micro-watts of power usage or data transmission is required to protect from sparking related accidents. Even Zener Barriers can help reduce risks due to wrong connections or cross connection due to cable damages.

In the field, due to various constrains many safety practices can be overlooked or circumvented. The Sensors and System design must be over-engineered in some cases to safeguard man-machine assets.


Pressure Control

Monday, June 01, 2009

Flow Measurement and Control

There are three Controls to be Adjusted to make a Proportional Flow Controller Perform Properly. This method has to be practiced and experience gained from it can be used to get very good and stable Control of the Flow or Velocity of a Fluid.

1. Set Point. (SP)

This is the Flow Rate at which you require the Fluid to be controlled at. Adjust the rate at which the fluid flow is expected to be controlled .

2. Process Value. (PV)

This is the Actual Flow Rate of the fluid in the flow sensor or its path. It is very important that the Flow Sensor is placed at a position in the fluid circuit in such a way to avoid cushions which may lead to oscillations around the Setpoint.

3. Proportional Band or Dead band. (PB)

Dead band or H % or Hysterisis are terms used in on / off Controllers in proportional controller we use the term proportional band.

4-20mA Control Signal


The Flow rate zone in which the Output is 4.1mA to 19.9mA which in turn Drives the AC-Drive >> Motor from 0% to 100% is the proportional Band. It is Given in % e.g. 50% PB of 200 lph SP is 100 lph. Band 150 lph - 250 lph

eg : The Motor is at 100% Drive 'on' till 150 lph and 'off' above 250 lph. ` Between 150 to 250 is the PB. A little above 150 the Motor reduces power gradually till at 250 it turns off. When SP=PV the output is 12mA (ideal) here the motor runs at 50% of the total power.

Selection of Motor / Drive and circuit Capacity:

The Motor / Drive Combination must at 12mA Control signal give a flow Rate at which the system is used for most of the time this gives good stability. The max flow rate setting required by system must be achievable at 80% of Motor Time Axis Power this is to make allowance for load and line regulations. The Flow Circuit should have normal resistance to flow to reduce Oscillations.

STC1000PFC - P = Proportional Control, F = Flow, C = Current Output.

Zoom Image

Flow Measurement and Control

Tuning or Adjusting a Proportional Flow Controller

Step # 1

Ensure Flow Sensor Output 4-20mA is properly connected to the Flow Controller polarity reversal will show reducing reading in the Display as Flow rises. The Motor / Drive used and Power selected must be able to bring the Flow more than the maximum required Flow rate directly without control (open loop).So when in doubt connect motor/drive and run at max power and observe maximum flow rate e. g. if max. flow obtained with Motor at 100% Power (direct) is
300 lph the STC1000PFC can control flow rates upto 260 lph.

Step # 2

Keep PB in middle position and power on system e.g. set Flow rate to 200 lph. Now Observe maximum overshoot. and adjust proportional band as in table. (PB Control is a 300 lph Single Turn Control with Ends.) SP 200 lph, PV (Process Value).

PV overshoot Proportional Band
10 % 220 lph or more
Near Maximum fully clockwise till end.
5 % 210 lph to 220lph
Middle of the PB Control or towards max.
2% 204 lph to 210 lph
Little above present setting.
Less than 200 lph Droop e. g. 190
PB is Critically set Do not Change.

After each change turn on system again to see response till 2 % or less variation or overshoot or oscillations are obtained.Flow Control Curve

Thumb Rule ! -

  • Increment PB to Decrease Overshoot.
  • Increment PB to Decrease Oscillations.
  • Stop adjustment when PV droops around SP with no oscillations.
  • Adjust EC to match SP = PV after PV is stable at a point less than SP.

If proportional band setting is maximum, fully clockwise turn till end (single turn pot) the motor will slowly ramp up to full flow speed and ramp down slowly to reduce flow.

If proportional band is at the minimum, the motor will go full speed till it comes close to the set flow rate and turn off abruptly almost like an on / off controller the motor may pulsate on & off near setpoint.

Step # 3

There is an additional control called Reset or Error Cal EC ( Integral) which is factory set for SP=PV 50% Power Output i.e. Output Control = 12mA. In certain cases after stable reading is obtained after adjusting or tuning PB the Flow may stabilize say at 195 lph for a set point of 200 lph the process is stable but a ten lphrees process error is present. this can be Corrected with EC or RESET POT at the rear panel (this is a endless 10 Turn Pot).

Adjust Error Cal provided in the back panel to increase Flow rate to 200 lph from 190 lph. when this is done give some time for system to respond after every 1/2 a turn 180 lph of the RESET (EC) control pot .

The RESET control is a Ten turn potentiometer like the SP potentiometer after 10 turns the direction of turning must change. Clockwise Increases Flow rate Anticlockwise decreases Flow rate. (at min. PB setting EC pot sets the On / Off or Operating Point).

Contents

Basic Electronics
Basics of Electronics
Product Production
Work Discipline
Testing Points
Learning Electronics
Electronics Theory

Production Notes
Prototype Fabrication
Electrical Circuits
Electromechanical


Library
Scots Guide Electronics
Engineering - Wikibooks
Design Lab - Jim Svoboda
DC Circuits UOG
Socratic Electronics
Blobz Guide Electric Circuits


Product Design
Product Development
Constant Current Source
Good Voltage Regulators
Insulation Resistance
Digital Insulation Tester
DN Schematic PCB 04
DN Product Design 07


Hobby Circuits
VU Meter Circuits
LED brightness control
555 Incredible Chip
Process Control
liquid level measurement
Thermocouples and RTD
Design ADC Interface uC
Thermocouple Amplifier
IA Instrumentation 02
Temperature on DMM
Optical Proximity Switch
Analog Mux - Data Acquisition


Test Measurement
Instrumentation Automation
NI Test and Measurement
DMM Digital Multi Meter
Oscilloscope in T&M
IA Automation 01
Build Instruments
Tektronix T&M Equipment
Educators Corner – Agilent


Power Electronics
UPS Background
Transformer Connections
DN Power Electronics 03
DN Power Electronics 02
Half Bridge Convertor SG3525


Embedded
Interfacing Microcontrollers
Embedded Process Control
80C31 8052 Microcontroller
Microprocessors and uC
Embedded Systems Design

Components
Good Voltage Regulators
Relays and Contactors
Potentiometers Trimpots
Prototype Boards Types
Types of Capacitors
Types of Switches
Resistors How they Work
Coils Transformers SMPS
Mains Transformers Types
DN Components Selection 05

Tutor Gadgets
Count-Up Timer
Digital Logic Gates
Electronics Tutors

History
Teaching Instruments
Charles Proteus Steinmetz
Muntzing a Circuit Design
Teralab Electronics projects
Historical Instruments


Tables, Charts, Videos
Binary and Hex
Resistor Color Code
Ohms Law
Giga, Tera, Pico, Nano
High Resistance Materials

Analog
School - Analog Design
DN Analog Basics 06
DN Op-Amps 01
TI Semiconductors