Facts of EMI and RFI from the Inside

Electromagnetic interference (or EMI, also called radio-frequency interference or RFI when in radio frequency) is disturbance that affects an electrical circuit due to either electromagnetic induction or electromagnetic radiation emitted from an external source.

Electromagnetic interference Wiki

Vertical polarized VHF- UHF biconical antenna

Vertical polarized VHF- UHF biconical antenna
170 – 1100 MHz with omni directional H-plane pattern

Who would know better about Radio Frequency Interference and ElectroMagnetic Interference more than the Hams or Amateur Radio Community.

If they have to communicate effectively using limited resources, they have to deal with EMI/RFI effectively, While they build their equipment or combat Noise from other Machines and Installations nearby.

This problem needs more practical involvement and experimentation to learn, compared to learning something like Digital Electronics.

Equipment and Electricals like SMPS, AC/DC Drives, Motors, Solenoids and CFL Lamps are to be built/reinforced for low EMI/RFI emission/radiation.

Radio Frequency Interference (RFI)

Sensitive Medical Equipment like ECG or even a Aircraft can be seriously affected by Noise.

Friday, June 15, 2018

Design Notes - Analog and Opamps - 01

Analog is the first thing in electronics. Valve Radios had Amplifiers and RF sections that were analog. Even the first computing methods are analog. Analog is close to Real Life parameter behavior. 

LM335 and LM336 -

LM335 is a temp sensor, LM335 . use it for temp for CJC. Temperature Sensors - RTDs and Thermocouples in  Temperature Measurement.

LM336-2.5 is an voltage Reference. precision 2.5V shunt regulator diodes, Applied as a precision 2.5V low voltage reference for digital voltmeters, power supplies or in opamp signal conditioning.

Current Loop -

4-20 ma will drive DC drives, motors and steam valves. It is a current loop, for long distance transmission, current loop is not prone to noise and hum, EMI RFI. As it is a small power transmission no loss of data, also many equipments can be in one data loop. A single transmitter with 4-20mA out can drive a strip-chart recorder, motor, controller and SCADA input. all in a series loop. Current loop is like 4-20 mA

Opamp Notes and Types
  • TL062, LF353, TL072, fet input. 1 tera ohm input imp.
  • OP07 higher price, 1 giga ohm. 75uV offset.
  • LF353 pin to pin replacement of TL062-72 and 82.
  • LM358 works on single supply too, low price, inp imp 1 meg.
  • LM324 Quad, works of batteries well.
  • All work best with dual +/- 5 V or more. LM7805 -LM 7905.
Analog Electronics: Basic Circuits of Operational Amplifiers

Examine the operation of the following circuits of operational amplifiers: inverting amplifier, summing amplifier, difference amplifier, differentiator, and integrator.

Remembering Bob Pease

Remembering Bob Pease

Points to Note -
  • Analog ground (opamps), digital ground (CMOS) and power ground (relays and LED) should be separate, (linked at root)
  • Glass epoxy PCB have high insulation resistance, above 10 tera ohms, and are not hygroscopic which means they do not drink water vapor, this makes them very suitable for precision instrumentation and sensitive circuits.
  • When you measure DC levels in 16bit accuracy or more you need resistors which have temp. coeff. of 10ppm, or you may have to put the entire circuit in a stable 45 deg oven. Thermoelectric effects, EMI, RFI, pA Leakage currents, ground loops, contact resistance all can make the readings drift and unusable.
  • High impedance points of circuit like 500 kilo ohm and above can pick up AC noise and DC leakage currents. this will affect the performance of circuit, so for DC you have to put a guard ring of the signal ground around that point in PCB. For RF you have to shield with things related to iron and mu metal, for low signals even a copper shield will do.
  • Percentage and ppm: when percentage becomes like 0.001% it is difficult to manage, so we use ppm-parts per million.5% means 5 parts in 100 parts. 23 ppm means 23 parts per million parts. 0.001% - shift the dp-decimal point four places to right it is 10ppm. 0.01% is 100ppm which is the variation of value of mfr resistors on temperature change.
Learn this at my Industrial Process Control Circuits

Thursday, June 14, 2018

Lightning Bolt damages Components

A ThunderBolt Zap can damage electronic parts. The Earth Leakage Circuit Breaker ELCB or Overload Breaker may Trip.

Surge Protection and Lightning Arrestors

Mains Strip Board should have protection, The EMI RFI filter, Varistors can help. Earthing and Lightning Arrestors should be good in the building.

The Blue ones are MOV Metal Oxide Varistors, sometimes they fail as a short circuit, so better to use a fast blow fuse. Then you see Gas Tube Arrestors that are even used in a Landline Terminal Box.

Surge Arrestors

A Surge Arrester is a device to protect electrical equipment from over-voltage transients caused by external (lightning) or internal (switching) events. Also called a surge protection device (SPD) or transient voltage surge suppressor (TVSS),

Line-Filter - A special class of capacitor is used in power-line (mains) filters.  Line filtering is a very tough application for a capacitor.

Achieving EMC for Dc-Dc Convertors - DC-DC converters, whether they be an off the shelf brick design or a discrete equivalent, are a source of EMI (Electromagnetic Interference). EMI is unwanted electromagnetic energy that propagates by radiation and conduction over system signal and power lines.

SMPS switch mode power supply design, PSpice simulation - These definitions should be considered relevant to a SMPS, and may not apply identically to other technical areas.